From Bulkheads to Decks: A Complete Look at Marine Fire Protection Systems & Solutions

From Bulkheads to Decks: A Complete Look at Marine Fire Protection Systems & Solutions featured image

Table of Contents

Share this post

Introduction: Fire at Sea Is Not Like Fire on Land

There’s a reason experienced mariners speak of fire with quiet respect. At sea, there’s nowhere to run. Every vessel — whether a bulk carrier crossing the Tasman, a gas tanker operating out of Australasia’s northern ports, or a passenger ferry navigating Cook Strait — is a self-contained world. When fire breaks out, containment isn’t just a compliance requirement. It’s the difference between a manageable incident and a catastrophe.

This is the fundamental truth that drives marine fire protection systems and solutions: the sea removes every option except prevention and containment. And yet, despite this reality, most available content about marine fire protection stops at the surface — covering detection systems or extinguishers without ever explaining the structural backbone that holds everything together.

This article changes that. We’re going to walk through every layer of a ship’s passive fire protection system, from the rated divisions in its bulkheads and decks to the often-overlooked penetration sealing solutions that are the most common point of failure in real-world marine fire incidents.

 

Beele RISE system installed

 

Why Marine Fire Protection Demands Its Own Standard

Marine environments are categorically different from commercial buildings or industrial facilities onshore. Ships operate in corrosive saltwater conditions, experience constant structural vibration, carry fuels and hazardous cargo, and must comply with international classification standards — all while being inspected by classification societies and flag state authorities at regular intervals.

According to the International Maritime Organization’s SOLAS (Safety of Life at Sea) convention, every vessel above a certain gross tonnage must comply with rigorous fire protection requirements across its structural divisions. SOLAS Chapter II-2 is dedicated entirely to construction, fire protection, fire detection, and fire extinction — and it sets out a detailed framework that governs how bulkheads, decks, and penetrations must perform under fire conditions.

What makes SOLAS unique — and what most content about marine fire protection misses — is that it distinguishes between structural fire protection (passive) and firefighting systems (active), requiring both to work independently and in combination. Failing either layer means failing compliance, and potentially failing a crew.

 

The Classification Framework: A-Class, B-Class, and C-Class Divisions Explained

At the heart of any ship’s fire protection design is its division classification system. Understanding these classes is essential for anyone specifying, installing, or auditing marine systems and solutions.

A-Class Divisions

A-class divisions are the gold standard in shipboard fire separation. These are bulkheads and decks constructed of steel or equivalent material, suitably stiffened, and designed to withstand smoke and flame penetration for the full duration of a onehour standard fire test. Within A-class, there are sub-ratings:

• A-60: Surface temperature on the unexposed side does not rise more than 139°C above ambient within 60 minutes

• A-30: Same criterion, but for 30 minutes

• A-15: Same criterion, but for 15 minutes

• A-0: Integrity only — the division must prevent the passage of smoke and flame for one hour, but with no insulation temperature requirement

Main vertical zones on passenger and cargo ships are divided by A-class bulkheads. These zones must not exceed 40 metres in length, creating fire-contained compartments across the vessel’s length.

B-Class Divisions

B-class divisions — bulkheads, decks, ceilings, and linings — are designed to prevent the passage of flame for at least the first 30 minutes of the standard fire test. B-class divisions must also limit temperature rise to no more than 139°C above ambient within 30 minutes. These are commonly used in accommodation and service spaces where A-class construction would add unnecessary weight.

C-Class Divisions

C-class divisions are constructed from approved non-combustible materials but are not required to meet smoke, flame, or temperature-rise performance standards. They are used in low-risk internal spaces where separation rather than fire resistance is the primary need.

What most articles don’t tell you is this: the classification of a division only holds if every penetration through that division — every pipe, cable, duct, and conduit — is sealed to at least the same rating. A single unsealed penetration through an A-60 bulkhead can compromise the entire fire zone. This is where marine fire protection systems and solutions most often fail in practice.

NOFIRNO® penetration seal installed

 

Penetration Sealing: The Most Overlooked Element in Marine Fire Safety

Modern vessels are threaded with thousands of pipes, cables, and ducts. Every time one of these services passes through a fire-rated bulkhead or deck, it creates a penetration — a potential breach in the fire separation strategy.

IMO Resolution A.754(18) governs the fire testing of penetration seals in A-class bulkheads and decks. Approved penetration sealing systems must be tested against the same fire exposure as the division they protect, and they must maintain both integrity (no passage of flame or hot gases) and insulation (temperature limits on the unexposed face).

This is where the detail matters enormously — and where Beele’s marine systems and solutions are specifically engineered to perform. Not all pipes and cables are the same: plastic pipes behave differently to metallic pipes in fire. Large diameter pipes require different sealing strategies to small bore tubing. Cable bundles need different products to single conductors.

Key considerations when specifying marine penetration seals include: • The fire rating required by the division (A-0, A-15, A-30, A-60) • The service type: plastic pipe, metallic pipe, cable, mixed service, or rigid ducting • The diameter and number of services passing through the penetration • Whether the bulkhead or deck is a watertight division (which adds further requirements) • The classification society involved — DNV, Lloyd’s Register, Bureau Veritas, ABS — each with their own type approval documentation requirements

NOFIRNO® deck penetration seal

One critical nuance that’s rarely published: penetrations in A-15 or A-30 bulkheads and decks must typically be insulated to A-60 standards, because that is the configuration under which most penetration sealing products have been fire tested. Specifying to the minimum division rating without checking the tested configuration can result in a non-compliant installation that still passes a visual inspection.

 

What Makes Marine Fire Sealing Different: The Five Challenges No One Talks About

Anyone who has worked in both building and marine fire protection knows that the marine environment is in a different category. Here are five challenges that are specific to vessels and that fundamentally change how marine systems and solutions must be designed:

  • Vibration and movement: Ships flex. Structural movement during sea passage creates constant micro-stress on every installed system. Fire seals must maintain their rated performance not just under static conditions but across years of dynamic loading.
  • Saltwater corrosion: Any metal components must be specified for marinegrade corrosion resistance. Standard galvanised fixings that would be acceptable in a commercial building will corrode rapidly in the marine environment.
  • Space constraints: Engine rooms, pipe tunnels, and cable runs on modern vessels are extraordinarily congested. Sealing solutions must be installable in confined spaces, sometimes with limited access to both faces of the division.
  • Retrofitting during service life: Unlike buildings, ships rarely get the luxury of a full shutdown for fire protection upgrades. Penetration seals often need to be installed or replaced while adjacent systems remain operational.
  • Classification society approval chains: A product that holds DNV type approval isn’t automatically acceptable to Lloyd’s Register. It’s essential to confirm that the products specified match the classification society that will survey the vessel.

Beele RISE frame installed in a vessel bulkhead

 

What Sets Purpose-Built Marine Fire Protection Apart

The difference between a generic fire sealing product and a purpose-built marine solution isn’t marketing — it’s documented, tested performance against marinespecific standards. Products designed for the marine environment carry:

  • Type approval certificates from major classification societies (DNV, Lloyd’s Register, BV, ABS, Class NK)
  • Test data to IMO Resolution A.754(18) for both bulkhead and deck configurations
  • Proven performance across the full range of services: plastic pipes, metallic pipes, single and multiple cables, mixed services, and rigid ducting
  • Technical support for specifying the correct solution to the correct rating for the specific installation

For marine operators, shipbuilders, and project managers across Australasia, working with a supplier that understands the complete classification system — not just the product datasheet — is what separates a compliant installation from one that becomes a problem at the next survey.

Beele’s marine systems and solutions cover every penetration type across A-class and B-class divisions, with classification ratings from A-0 through to A-60. Every product is backed by fire test data and type approval documentation, and the technical team can assist with system selection from first principles.

RISE® and NOFIRNO® cable sealing system

Conclusion: Fire Safety at Sea Starts in the Structure

Marine fire protection is not a single product or a single system. It is a layered strategy that starts with rated bulkheads and decks, works through every penetration in those divisions, and is supported by active detection and suppression systems — all governed by international standards that are more specific and more demanding than most people appreciate.

The gap between a vessel that is genuinely fire-safe and one that simply passes a routine inspection often comes down to the details: the right penetration sealing product, correctly installed, with the right type approval for the right classification society.

For vessel owners, naval architects, shipbuilders, and project managers across Australasia, getting those details right from the start is the only approach that holds up when it matters.

Beele’s marine team in Australasia is available to assist with system selection, technical documentation, and classification compliance across all vessel types and division ratings.

 

Frequently Asked Questions

1. What is the difference between A-60 and A-0 marine fire divisions?

Both A-60 and A-0 are A-class divisions, meaning they are constructed from steel or equivalent material and must prevent the passage of smoke and flame for a full hour. The difference is in insulation performance: an A-60 division must also limit the temperature rise on its unexposed face to no more than 139°C above ambient for 60 minutes. An A-0 division only needs to maintain integrity — it has no insulation requirement. A-60 is typically specified between high-risk spaces such as machinery rooms and accommodation areas.

2. Do penetration seals need to match the rating of the bulkhead they penetrate?

Yes — and the detail matters more than most people realise. A penetration through an A-60 bulkhead must be sealed to A-60 performance. However, because many penetration sealing systems have only been fire-tested in an A-60 configuration, penetrations in A-15 or A-30 bulkheads often still require A-60 insulation to match the tested configuration. Always check the type approval certificate to understand the tested installation parameters before specifying.

3. Can the same penetration sealing product be used for both pipes and cables?

Generally, no. Pipes and cables behave very differently under fire conditions — particularly plastic pipes, which can burn away and leave an open void. Products designed for cable penetrations are not necessarily tested or rated for pipe penetrations, and vice versa. Marine systems and solutions must be specified to the actual service type passing through the division. Mixed-service penetrations (pipes and cables in the same opening) require specifically tested and approved solutions.

4. How does SOLAS govern fire zone compartmentalisation on passenger vessels?

SOLAS Chapter II-2 requires passenger vessels to be divided into main vertical zones by A-class bulkheads. Each zone must not exceed 40 metres in length. This compartmentalisation strategy is designed to limit fire spread and provide time for evacuation and suppression. Every penetration through these A-class zone boundaries must maintain the integrity and insulation of the division — making penetration sealing a fundamental element of SOLAS compliance, not an afterthought.

5. What is the IMO’s ‘Safe Return to Port’ requirement, and how does it affect fire protection?

The IMO’s Safe Return to Port (SRTP) regulations, introduced under SOLAS and applicable to passenger ships built after 2010, require that vessels be capable of returning to port under their own power following a casualty scenario including a fire. SRTP requires redundancy and survivability in critical systems, and it places additional requirements on fire zone boundaries and penetration integrity in the spaces that house those systems.

6. How often should marine fire penetration seals be inspected or replaced?

Marine penetration seals should be inspected as part of each periodic survey cycle with the relevant classification society – typically every 2.5 years for annual and intermediate surveys, and every 5 years for special (renewal) surveys. Any modification to services passing through a sealed penetration requires the seal to be reinstated to its original tested and approved configuration.